AnaGate CAN X2User ManualAnalytica GmbHA. Schmidt, Analytica GmbH

Strany 2 - AnaGate CAN X2: User Manual

Description3 © 2007-2014 Analytica GmbH1.4. Interfaces and plugs1.4.1. AnaGate CAN X2Figure 1.1. Top view AnaGate CAN X2The upper connector strip o

Strany 3 - Table of Contents

Description4 © 2007-2014 Analytica GmbHPin Description1 GND2 CAN_L3 not connected4 CAN_HTable 1.2. Pin layout, CAN plug, upperconnector stripA

Strany 4 - List of Figures

Description5 © 2007-2014 Analytica GmbHACTLEDThis green LED lights up when the AnaGate CAN Gatewayis processing incoming and outgoing CAN messages.ERR

Strany 5 - List of Tables

6 © 2007-2014 Analytica GmbHChapter 2. Configuration2.1. Initial installationFirst the AnaGate CAN Gateway must be supplied via the power plug with

Strany 6 - List of Examples

Configuration7 © 2007-2014 Analytica GmbHcan be e.g. used. If neccessary the settings of the network interface onthe configuration pc has to be change

Strany 7 - Introduction

Configuration8 © 2007-2014 Analytica GmbHThe inputs will be taken over immediately after clicking the button Save settingsand saved permanently on the

Strany 8 - Chapter 1. Description

Configuration9 © 2007-2014 Analytica GmbHoffline The CAN controller is not active on theCAN bus (offline).normal Normal operating mode. The

Strany 9 - 1.3. Scope of delivery

Configuration10 © 2007-2014 Analytica GmbHFigure 2.4. HTTP interface, CAN settingsReception timer interval This value specifies the frequency wh

Strany 10 - 1.4. Interfaces and plugs

Configuration11 © 2007-2014 Analytica GmbHFigure 2.5. HTTP interface, StatusTCP Receive Number of via TCP/UDP received CAN messages (CANfirmwa

Strany 11

Configuration12 © 2007-2014 Analytica GmbHof timeouts during transmission or of overloading the CANbus concerning the current used baud rate.CAN Recei

Strany 12

AnaGate CAN X2: User ManualAnalytica GmbHby A. SchmidtThis document was generated with DocBook at 2014-10-31 12:48:28.PDF-Datei (dtsch.): AnaGate-CAN-

Strany 13 - Chapter 2. Configuration

Configuration13 © 2007-2014 Analytica GmbHFigure 2.6. HTTP interface, Lua settingsBrowse... Opens a file upload dialog to select a Lua script file.Up

Strany 14 - 2.2. Network settings

Configuration14 © 2007-2014 Analytica GmbHTo start the execution of a script click on the button Start.Via button Delete a script can be deleted on th

Strany 15 - 2.3. CAN settings

Configuration15 © 2007-2014 Analytica GmbHWarningFor thermical reasons the maximum power dissipation of the outputstage PV must not exceed 0.

Strany 16 - 2.4. Advanced settings

Configuration16 © 2007-2014 Analytica GmbH• Digit 0: 10x flashing (200ms delay between each flash)• Dot: 1x very fast flashBetween two single digits a

Strany 17 - 2.5. Device status

17 © 2007-2014 Analytica GmbHChapter 3. Fields of applicationIf the AnaGate CAN Gateway is connected to the CAN bus, mind the following facts:• CAN_L

Strany 18

Fields of application18 © 2007-2014 Analytica GmbH• Self-created batch files which are executed via the included Lua interpreter withintegrated AnaGat

Strany 19

Fields of application19 © 2007-2014 Analytica GmbH• The baudrate of the partner device. The baudrate of the parter device isindependant o

Strany 20

Fields of application20 © 2007-2014 Analytica GmbHTo interconnect the two CAN interface on a single device, the own IPaddress or 127.0.0.1

Strany 21 - 2.7. Analogue IO

21 © 2007-2014 Analytica GmbHAppendix A. FAQ - Frequently askedquestionsHere is a list of frequently asked questions.A.1. Common questionsQ: No netwo

Strany 22 - 2.8. Factory reset

FAQ - Frequentlyasked questions22 © 2007-2014 Analytica GmbHQ: No network connection after changing the network addressA: After changing the network

Strany 23

iii © 2007-2014 Analytica GmbHTable of ContentsIntroduction ...

Strany 24 - 3.1. Gateway mode

FAQ - Frequentlyasked questions23 © 2007-2014 Analytica GmbHDevice Port numberAnaGate I2C X7 5100, 5200, 5300, 5400,5500, 5600, 5700AnaGate CAN 500

Strany 25 - 3.2. Bridge mode

FAQ - Frequentlyasked questions24 © 2007-2014 Analytica GmbHNoteit may work with lower baud rates without termination, but it isrecommended

Strany 26

25 © 2007-2014 Analytica GmbHAppendix B. Technical supportThe AnaGate hardware series, software tools and all existing programming interfacesare deve

Strany 27 - Example 3.1. Settings.ini

26 © 2007-2014 Analytica GmbHAbbreviationsI2C Inter-Integrated CircuitSCL Serial Clock LineSDA Serial DAta LineSPI Serial Peripheral InterfaceCLK Cloc

Strany 28 - A.1. Common questions

27 © 2007-2014 Analytica GmbHBibliographyBooks[LuaRef2006-EN] Roberto Ierusalimschy, Luiz Henrique Figueiredo, and Waldemar Celes.Copyright ©

Strany 29 - C:\>arp -a

iv © 2007-2014 Analytica GmbHList of Figures1.1. Top view AnaGate CAN X2 ... 32.1. HTT

Strany 30

v © 2007-2014 Analytica GmbHList of Tables1.1. Technical data, AnaGate CAN X2 ... 21.2. Pin la

Strany 31

vi © 2007-2014 Analytica GmbHList of Examples3.1. Settings.ini ...

Strany 32 - Internet

vii © 2007-2014 Analytica GmbHIntroductionThis document describes the features and objectives of the CAN-Ethernet gatewayAnaGate CAN X2.This device is

Strany 33 - Abbreviations

1 © 2007-2014 Analytica GmbHChapter 1. DescriptionThe AnaGate CAN Gateway connects a PC, an embedded PC or an other generaldevice to one

Strany 34 - Bibliography

Description2 © 2007-2014 Analytica GmbH1.2. SpecificationTechnical aspect SpecficationDIN rail casing 100mm x 125 mm x 50mmMeasurementsWeight approx.